Uniflair Monoblock Wall Mounted Unit, External Installation with Upflow Air Discharge and Direct Free-Cooling

Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual

Product Description


Uniflair Monoblock Wall Mounted Unit, External Installation with Upflow Air Discharge and Direct Free-Cooling
Uniflair Wall Mount Room Cooling Features & Benefits

Model:  WMF

CONVENIENCE

  • Self Contained:  The unit is quickly and easily installed without the need for refrigerant lines or remote heat exchangers.
  • Input Power:  14600 Watts

AVAILABILITY

  • Dual power inputs:  (Optional) Dual power supplies for incoming power redundancy
  • Redundant Components:  Single points of failure in the system have redundant components to maintain availability and reliability.
  • Scroll compressors:  Utilize few moving parts for increased reliability and life expectancy.
  • Active response control:  Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Direct drive motors:  Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

MANAGEABILITY

  • Microprocessor controller:  Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
  • Building Management Systems:  Units are designed to work with the most common BMS systems including BACnet and Modbus.
  • Network interface:  Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
  • Local area network:  Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
  • Direct Free Cooling:  Utilizes outdoor air when ambient air temperature can help support cooling loads.

ECONOMY

  • High performance technological solutions
    Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption
  • Modular strategy
    Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.

SERVICE

  • Service monitoring
    All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
  • Operational Service
    Allows critical components to be maintained/replaced while the system is in operation.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.